KM900 Plus Hand-held Combustion Analyser

Strany 2

KANE900 Plus Operators Manual Page 9 4.3.2 Line Scroll Mode Line scroll mode allows you to customise the display. Use the and keys to change th

Strany 3

KANE900 Plus Operators Manual Page 10 4.4 Sampling the Flue Gas Once the automatic calibration procedure has been completed and the specific

Strany 4

KANE900 Plus Operators Manual Page 11 4.6 Regular Checks During Sampling Care must be taken at all times not to exceed the analysers operating sp

Strany 5 - 1.4 Analyser Connections

KANE900 Plus Operators Manual Page 12 4.8 Electromagnetic Compatibility The European Council Directive 89/336/EEC requires that electronic equipm

Strany 6 - 3. FIRST TIME USE

KANE900 Plus Operators Manual Page 13 5. MOVING THROUGH THE MENUS 5.1 Basic Operation From the MAIN DISPLAY NETT C 0.0 O2

Strany 7 - (44)-1707-375550

KANE900 Plus Operators Manual Page 14 5.2 Menu Options and Settings 5.2.1 Main Menu The MAIN MENU consists of 4 sub menus which are shown below

Strany 8

KANE900 Plus Operators Manual Page 15 To enter the user fuel select ‘User Fuel’ and Press USER FUEL K1g K_2K_4: 0.000: 0.00 : 00 K1n K_

Strany 9

KANE900 Plus Operators Manual Page 16 Selecting YES and will display the following screen. RESET SENSORS O2 % : 20.9 CO & NO = 0 PRESS ENT

Strany 10

KANE900 Plus Operators Manual Page 17 5.2.4 Display Menu LIGHT MODE CONTRAST : OFF : 8-PAGE : DEFAULT Allows the configuration of the display to

Strany 11

KANE900 Plus Operators Manual Page 18 Once an alarm has been exceeded the display will flash every two minutes warning the user of an alarm state a

Strany 12

KANE900 Plus Operators Manual Page 1 1. ANALYSER LAYOUT AND FEATURES 1.1 Instrument Features and Keypad ON

Strany 13

KANE900 Plus Operators Manual Page 19 Header : Allows two lines of 20 characters to be programmed into the analyser. The header appears on the top

Strany 14

KANE900 Plus Operators Manual Page 20 6. PRINTING INFORMATION Supplied as accessories for the KANE900 Plus are an infra-red thermal printer

Strany 15

KANE900 Plus Operators Manual Page 21 6.2 Standard Printout The standard printout is:-

Strany 16

KANE900 Plus Operators Manual Page 22 7. STORING AND RETRIEVING DATA The KANE900 Plus can store combustion tests. Once stored, the data can be

Strany 17

KANE900 Plus Operators Manual Page 23 To print the data press . In the screen shown above locations 1 to 10 will be printed. During printing th

Strany 18

KANE900 Plus Operators Manual Page 24 8. AVERAGE OF THREE 8.1 Storing Ensure the instrument is switched on and in the main screen. In the 4-pag

Strany 19

KANE900 Plus Operators Manual Page 25 Get into the average of three viewing mode, “Ave View” as above. Offer a printer to the instrument in the u

Strany 20

KANE900 Plus Operators Manual Page 26 9. MAINTENANCE 9.1 Emptying and Cleaning the In-line Water Trap The in-line water trap should be checked a

Strany 21 - Printing

KANE900 Plus Operators Manual Page 27 10. PROBLEM SOLVING The following is a list of problems that may occur on the instrument through its operati

Strany 22 - 6.2 Standard Printout

KANE900 Plus Operators Manual Page 28 12. PRODUCT SPECIFICATION Parameter Resolution Accuracy Range Temp Measurement Flue Temperature Inlet Te

Strany 23

KANE900 Plus Operators Manual Page 2 1.2 Instrument Layout (Rear)

Strany 24

KANE900 Plus Operators Manual Page 29 APPENDICES A - Main Display Parameters The parameters and their meanings are detailed as follows : - DATE

Strany 25 - 8.3 Printing

KANE900 Plus Operators Manual Page 30 AMBIENT : Temperature measured by the internal sensor, used in the NET (Ta) temperature calculation if an

Strany 26

KANE900 Plus Operators Manual Page 31 B. COMBUSTION EFFICIENCY CALCULATION The efficiency calculation is based upon British Standard BS845. This

Strany 27 - 9. MAINTENANCE

KANE900 Plus Operators Manual Page 32 Calculated data: Tnet = Net Temperature % CO2 content in flue gas % Dry Flue Gas losses % Wet los

Strany 28 - 10. PROBLEM SOLVING

KANE900 Plus Operators Manual Page 33 C. CALCULATION OF FUEL DATA For any fuel not specified by Kane International the net calorific value, gros

Strany 29 - 12. PRODUCT SPECIFICATION

KANE900 Plus Operators Manual Page 34 D. ELECTROMAGNETIC COMPATABILITY (CE) STATEMENT This product has been tested for compliance with the

Strany 30 - APPENDICES

KANE900 Plus Operators Manual Page 35

Strany 31

KANE900 Plus Operators Manual Page 36 Thank you for buying this instrument. Before use, please register on our website www.kane.co.uk

Strany 32

CONTENTS Page No: 1. ANALYSER LAYOUT AND FEATURES ...1-4 1.1 Instru

Strany 33

8. AVERAGE OF THREE...24-25 8.1 Storing .

Strany 34

KANE900 Plus Operators Manual Page 3 1.3 Standard Probe Configuration

Strany 35

KANE900 Plus Operators Manual Page 4 1.4 Analyser Connections Gas Connectionto InstrumentParticle FilterIn-line Water TrapNeoprene HoseFlue Tempe

Strany 36

KANE900 Plus Operators Manual Page 5 2. SAFETY WARNING This analyser extracts combustion gases that may be toxic in relatively low concentrations

Strany 37

KANE900 Plus Operators Manual Page 6 4. NORMAL START UP SEQUENCE 4.1 Every Time You Use The Analyser BEFORE SWITCH-ON CHECK THAT: the partic

Strany 38 - CONTENTS

KANE900 Plus Operators Manual Page 7 Once the time has reached zero an audible beep will be heard and will show the selected fuel on the following

Strany 39

KANE900 Plus Operators Manual Page 8 4.3 Main Displays The main display can be changed to show either 4 or 8 parameters at one time. Two options a